Liquid Measurement
  LM Home
  Literature Index
  News
  Contact Information
  Mass Inventory Management
  RML2000 LPG Mass Flow Meter
  E4000 Electronic Register
  E1000 Electronic Register
  4 MT Petroleum Tank Truck Meter
  4D MT LPG Tank Truck Meter
  4D MD LPG Dispenser
  Type 4 Flowmeters
  Type 40 Flowmeters
  Very Low Flow Flowmeters
  Type 4 Size 3" Flowmeters
  F-RAMS Handheld Computer
  Latin American Products
  Type S Magnetic Drive
  Type MP Oscillating Piston
  Pulsmate Electronic Register
  Type S High Pressure Flowmeter
  Type S Industrial Flowmeter
  Mass Flow Transducers
  NexGen Mass Flow Transmitter
  DATAMATE Mass Flow Computer
  600 Series Register
  800 Series Register
  Bulk Air/Vapor Eliminator
  Digital Pulse Transmitters
  Model 157 Register
  BATCHMATE 1500
  Auto-Stop Switches
 

Auto-Stop Switches

Neptune Model 23 Auto-Stop Switches used with 800 series preset registers extend the Auto-Stop feature to electrically operated systems for the remote actuation of valves, pumps or other accessory equipment. They can be supplied on new flowmeters or added to flowmeters already designed for Auto-Stop operation. They can be used with any 800 Series Preset Register.

There are two types of Auto-Stop Switches, 23A and 23B. They are identical in outward appearance; however, the Model 23A is a two-stage switch used with actuated valves and the Model 23B is a single stage switch.

Model 23A: The Model 23A is designed to be used only with a double-trip Auto-Stop Register. The Model 23A provides two switch closures for two-stage shutdown of solenoid valves with the final closure also de-energizing the pump if needed. No mechanical valve is needed with the Model 23A switch. Model 23A switches are double-pole double-throw (DPDT).

Model 23B: The Model 23 B can be used with either a single trip or double trip Auto-Stop Register. Model 23B Switches provide one switch closure for single trip valve shutdown and/or pump de-energizing. They may be used with or without an auto-stop valve. Model 23B switches fit to the rear housing of the auto-stop register and allow the operator to electrically energize and de-energize some other device in sequence with the auto-stop register. The Model 23B switch is commonly wired to a motor starter for a pump. When activating the mechanical batch operation at the auto-stop register, the pump is energized at the same time. The switch closes and the pump is de-energized at the end of the batch. The Model 23B switch may be used with the auto-stop register even if a mechanical valve is not used. In these cases, the Model 23B starts and stops the flow for approximate batching application. Model 23B switches are single-pole double-throw (SPDT).

Tech Sheet

© 2009 Itron All rights reserved.     Contact Us  |  Privacy  |  Site Map